Parameter Data Format 
 
5.1.1  Read/Write Error Recovery Parameters (Page Code = 1)   
Table 5.1 lists the format of the page descriptor of this MODE SELECT parameter. 
Table 5.1  MODE SELECT parameters: read/write error recovery parameters  
 Bit 
Byte 
7 6 5 4 3 2 1 0 
0 0 0 0 0 0 0 1 
X'0A' (Page Length) 
AWRE 
ARRE TB  RC  ERR PER DTE DCR 
 
Default 
1 1 0 0 1 0 0 0 
 
Variable 
1 1 1 1 1 1 1 1 
READ RETRY COUNT  
 Default 
X'3F' 
 Variable 
X'FF' 
Correctable Bit Length 
 Default 
X'FF' 
 Variable 
X'00' 
X'00' (Head Offset Count) 
X'00' (Data Strobe Offset Count) 
7 X'00' 
(Reserved) 
WRITE RETRY COUNT  
 Default 
X'3F' 
 Variable 
X'FF' 
9 X'00' 
(Reserved) 
10-11 
Recovery Time Limit 
 Default 
X'7530' 
 Variable 
X'FFFF' 
(=63
times) 
(=255 bits
or more) 
(=30s)
 
(=63 
times)
 
 
282 