Fujitsu MBA3147RC Manuel D’Utilisation

Page de 439
Parameter Data Format 
 
This field is enabled by the MODE SENSE command.  This field indicates 
the beginning of the active notch or, if the active notch is zero, the beginning 
of the logical unit (HDD). 
f. Ending 
Boundary 
This field is valid in the MODE SENSE command.  This field indicates the 
ending of the active notch or, if the active notch is zero, the ending of the 
logical unit (HDD). 
g. Page 
Notch 
This is a bit map which shows whether or not other mode pages are being 
changed if the device is notched.  The most significant bit of this field 
corresponds to page code 3Fh and the least significant bit corresponds to page 
code 00h.  If it is specified, the HDD disregards this value. 
 
5.1.9  Port Control Parameter (Page Code = 19) 
This page is used to set parameters concerning data transfer of the drive and 
to refer to the current settings and maximum settings of these parameters. 
The support status on this page is as follows: 
 
Sub page 
Code parameter 
Support status 
Short page 
Short format 
Supported 
Long page 00h 
Not allowed 
− 
Long page 01h 
Phy Control And Discover subpage 
Supported 
Long page 02h 
Shared Port Control subpage 
Not supported 
E0h-FEh Vendor 
specific 
− 
FFh 
Return all subpages for the port 
control Page 
Supported 
 
310 
C141-C013