5.2  Log Parameters 
5.2.9  Application Client Page (X'0F')  
Table 5.54  Application client page (X'0F') 
 Bit 
Byte 
7 6 5 4 3 2 1 0 
0 0 0 0 1 1 1 1 
1 X'00' 
(Reserved) 
Page Length (MSB) 
Page Length (LSB) 
 
All of the following parameters have this header. 
Page Length will be defined based on the value of Parameter Pointer.  (CDB 5-6) 
•  General usage application client parameter data (page 0F, code 0000-003F)  
Table 5.55  General usage application client parameter data  
(page 0F, code 0000-003F) 
 Bit 
Byte 
7 6 5 4 3 2 1 0 
(MSB) 
 
X'0000'-X'003F' (Parameter code) 
 
(Application Client Parameter) 
(LSB)
DU DS TSD
ETC
TMC  LBIN LP 
1 0 0 0 0 0 1 1 
X'FC' (Parameter Length) 
8 (MSB) 
 
 
258 
General Usage Parameter Bytes 
259 (LSB)
 
The values stored in the General usage parameter bytes represent data sent to the 
device server in a previous LOG SELECT command.  If a previous LOG SELECT 
command has not occurred, the data is zero. 
~
 
~
 
~
 
~
 
~
~