Table 7.5  SMART ASC/ASCQ 
ASC 
ASCQ 
Description 
5D 
12 
The value of the read error rate attribute has reached its 
threshold. 
 
14 
The value of the G-list update frequency attribute has 
reached its threshold. 
 
41 
The value of the write error rate attribute has reached its 
threshold. 
 
43 
The value of the seek error rate attribute has reached its 
threshold. 
 
56 
The value of the spin-up attribute has reached its threshold. 
 
64 
The value of the number-of-remaining-alternate-sectors 
attribute has reached its threshold. 
 
FF 
Reporting in TEST mode. 
0B 
01 
The device temperature has exceeded its threshold. 
 
Failure prediction data is always logged and analyzed regardless of the setting of 
the "DExcpt" bit (MODE SELECT parameter on page 1C).  (The "DExcpt" bit 
value specifies whether to allow reporting as described in Section 7.6.4.) 
7.6.3  Failure prediction method 
a.  Read error rate attribute 
The HDD monitors the number of read errors that have occurred during read 
processing, in relation to the number of sectors that have been actually read 
and the number of sectors contained in the sample.  If the number of read 
errors reaches the threshold, the HDD considers that a failure prediction 
reporting condition has developed. 
The read sectors and read errors counted include those involved in read 
processing that was explicitly performed by READ commands or performed 