Fujitsu MAU3147NC/NP Manuel D’Utilisation

Page de 130
C141-E205 
7-3 
7.2 
Sense Data Analysis 
For details of sense data, refer to Chapter 5 “Sense Data Error Recovery Methods” in the 
SCSI Logical Interface Specifications. 
 
7.2.1 
Error information indicated with sense data 
 
Subsection 7.2.2 onwards explain troubleshooting using sense data. 
 
Table 7.1 lists the definition of sense data. 
Table 7.1 
Definition of sense data 
Sense data 
 
Sense 
key 
Additional 
sense code 
Additional 
sense code 
qualifier 
 
00 
00 
00 
Operation was normal. 
0C 
03 
A write to a disk terminated abnormally. 
4 32 
40 
C4 
01 
xx 
xx 
Failed to update the defect list due to a disk medium write error, etc. 
An error occurred in power-on self-diagnosis.  
A drive error occurred. 

1x 
1x 
xx 
xx 
A disk read error occurred. 
A disk read error occurred. 
1D 
00 
Data discrepancy found by VERIFY command byte check. 
 
 
 
 
4 or B 
 B 
 
2x 
3D 
90 
 
 
44 
47 
49 
4D 
 
4E 
xx 
00 
00 
 
 
xx 
xx  
00 
xx 
 
00 
An SCSI error, such as an invalid operation code, occurred. 
The Reserve bit of the IDENTIFY message was set to 1. 
The RESERVE or RELEASE command cannot be executed 
because the SCSI ID of the INIT was not posted in the 
SELECTION phase. 
A hardware error occurred inside IDD. 
A parity error occurred in the SCSI data bus. 
An unmounted or inappropriate message was received. 
Before completion of a command, a command with the same tag 
number was issued. 
An overlap command was issued. 
 
Definition