5-8 
C141-E205 
5.3.2  
Each mode setting 
(1) 
Setting terminator power supply 
 
Refer to Table 5.2 for controlling the supply of power from the drive to the SCSI terminator power 
source (TERMPOW).  
 
For information on NP model, refer to Figures 5.2 and 5.3. 
Table 5.2 
Setting SCSI terminator power supply (NP model) 
Supply on/off of SCSI terminator power from 
IDD 
Pin pair 23/24 of CN2 
(TRMPOW/TRMPOW) 
Supply off 
Open 
Supply on 
Short (*1) 
*1.  Set at factory shipment. 
 
For NC model, the function of the terminator power supply setting is not supported. 
(2) 
Motor start mode 
 
Set how to control the starting of the IDD spindle motor according to Table 5.3.  This setting only 
determines the operation mode when the power supply is turned on or the microcode is 
downloaded.  In both modes, stopping or restarting the spindle motor can be controlled by 
specifying the START/STOP UNIT command. 
Table 5.3 
Motor start mode setting  
NC model (*3) 
NP model 
Start timing of the spindle motor 
Pin 38 of CN1 
(RMT START) 
Pin 78 of CN1 
(DYLD START) 
Pin pair 11/12 of 
CN2 
(GND/RMSTART)
Starting of the motor is controlled 
with the START/STOP UNIT 
command. 
Short 
Open or Short 
Open 
The motor is started immediately after 
the power supply is turned on or after 
the microcode is downloaded. 
Open Open 
Short 
(*1) 
The motor is started after the elapse 
of a delay time that is based on the 
SCSI ID.  The delay time is provided 
immediately after the power supply is 
turned on or after the microprogram is 
downloaded. 
Open Short  (*2) 
*1.  Set at factory shipment. 
*2.  For NP model, delay starting of spindle motor is supported by the CHANGE  DEFINITION 
command only. 
*3.  To set the setting terminals on NC models to short, apply voltage ranging between-0.3 V and 0.8 
V to the setting terminals externally.  To set the setting terminals on NC models to open, apply 
voltage ranging between 2.0 V and 5.5 V to the setting terminals from an external source. 
 
Refer to Subsection 3.1.10 “START/STOP UNIT (1B)” in the SCSI Logical Interface 
Specifications for details of the START/STOP UNIT command.