Adaptec MAN-FC2002-001 Manuel D’Utilisation

Page de 110
Configurations
59
Dual RAID 
Controller 
Configuration
In this configuration two RAID Controllers are installed in 
the enclosures I/O slots.
Note: The following configuration procedures refer to 
connecting the 2Gb SANbloc Series directly to the host 
system. It is also possible to connect the system using a Hub/
Switch.
CAUTION: Before working on the enclosure, ensure that anti-
static precautions have been taken. The minimum requirement is 
an anti-static wrist strap and grounding wire.
To connect this configuration to a host system, follow this 
procedure:
Connecting Dual RAID Controllers to a Host Sys-
tem
Note: This example configuration assumes that the RAID 
enclosure is being attached to two separate host systems, 
each containing two HBA’s. Other configurations, such as one 
host with 4 HBA’s are also possible.
1
Plug two host cables in to the host connectors of the first RAID 
controller (one cable into each FC connector).
2
Plug the opposite ends of these cables into the HBA’s of the first 
host system (see Figure 4-7)
3
Plug two host cables in to the host connectors of the second 
RAID controller (one cable into each FC connector).
4
Plug the opposite ends of these cables into the HBA’s of the 
second host system (see Figure 4-7)