Lenovo 8176 Manuel D’Utilisation

Page de 228
Diagnostic
 
Error
 
Code
 
FRU/Action
 
001-027-XXX
 
System
 
Configuration/Setup
 
error
 
1.
   
Run
 
Setup
 
2.
   
Flash
 
the
 
system.
 
See
 
3.
   
System
 
board
 
001-032-XXX
 
System
 
Device
 
Controller
 
failure
 
System
 
board
 
001-034-XXX
 
System
 
Device
 
Buffer
 
Allocation
 
failure
 
1.
   
Reboot
 
the
 
system
 
2.
   
Flash
 
the
 
system.
 
See
 
3.
   
Run
 
memory
 
test
 
4.
   
System
 
board
 
001-035-XXX
 
System
 
Device
 
Reset
 
condition
 
detected
 
System
 
board
 
001-036-XXX
 
System
 
Register
 
error
 
System
 
board
 
001-038-XXX
 
System
 
Extension
 
failure
 
1.
   
Adapter
 
card
 
2.
   
System
 
board
 
001-039-XXX
 
System
 
DMI
 
data
 
structure
 
error
 
1.
   
Flash
 
the
 
system.
 
See
 
2.
   
System
 
board
 
001-040-XXX
 
System
 
IRQ
 
failure
 
1.
   
Power-off/on
 
system
 
and
 
re-test
 
2.
   
System
 
board
 
001-041-XXX
 
System
 
DMA
 
failure
 
1.
   
Power-off/on
 
system
 
and
 
re-test
 
2.
   
System
 
board
 
001-195-XXX
 
System
 
Test
 
aborted
 
by
 
user
 
Information
 
only
 
Re-start
 
the
 
test,
 
if
 
necessary
 
001-196-XXX
 
System
 
test
 
halt,
 
error
 
threshold
 
exceeded
 
1.
   
Press
 
F3
 
to
 
review
 
the
 
log
 
file
 
2.
   
Re-start
 
the
 
test
 
to
 
reset
 
the
 
log
 
file
 
001-197-XXX
 
System
 
test
 
warning
 
1.
   
Make
 
sure
 
the
 
component
 
that
 
is
 
called
 
out
 
is
 
connected
 
and/or
 
enabled.
 
See
 
2.
   
Re-run
 
test
 
3.
   
Replace
 
the
 
component
 
that
 
is
 
called
 
out
 
in
 
warning
 
statement
 
4.
   
Replace
 
the
 
component
 
under
 
test
 
001-198-XXX
 
System
 
test
 
aborted
 
1.
   
If
 
a
 
component
 
is
 
called
 
out,
 
make
 
sure
 
it
 
is
 
connected
 
and/or
 
enabled.
 
See
 
2.
   
Flash
 
the
 
system
 
and
 
retest.
 
See
 
3.
   
Go
 
to
 
 
Chapter
 
7.
 
Symptom-to-FRU
 
Index
 
63