Emerson MVME2500 Manuel D’Utilisation

Page de 146
Memory Maps and Registers
MVME2500 Installation and Use (6806800L01H)
101
5.6.4
Counter High and Low Word Registers
When enabled, the tick timer counter register increments every microsecond. Software may 
read or write the counter at any time.
Table 5-26 Counter High Word Registers  
REG
Tick Timer 0 Counter Value High Word   - 0xFFC80208
Tick Timer 1 Counter Value High Word   - 0xFFC80308
Tick Timer 2 Counter Value High Word   - 0xFFC80408
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Field
TickTimer Counter Value High Word (16-bits)
OPER
R/W
RESET
0x0000
Table 5-27 Counter Low Word Registers
REG
Tick Timer 0 Counter Value Low Word   - 0xFFC8020A
Tick Timer 1 Counter Value Low Word   - 0xFFC8030A
Tick Timer 2 Counter Value Low Word   - 0xFFC8040A
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Field
TickTimer Counter Value Low Word (16-bits)
OPER
R/W
RESET
0x0000