Multi-Tech Systems ISI4608-PCI Manuel D’Utilisation

Page de 70
48
ISI4608-PCI User Guide
The ISI460x-PCI cards and their configurations will be auto-detected by
the driver.
You can manually load the firmware into all of the installed ISI cards
simultaneously by executing the 'frmld' utility in the installation folder.
The firmware to all the installed cards can be manually loaded by
executing the 'firmld' utility in the installation folder. This utility
requires the firmware files (.bin) to be located in the /usr/local/ISICOM/
folder.
LINUX: Setting the baud rate
The 'stty' utility can be used to set the baud rate of a particular port.
For example, to set the baud rate of the first port on the first card
(ttyM1a) to 38400 bps, execute '
stty 38400 < /dev/ttyM1a
'.
The current baud rate can be viewed by executing '
stty < /dev/
ttyM1a
'.
LINUX: Verifying the ports
Terminal utilities like 'minicom' can be used to verify the ports, 'talk'
to the modem, and dial out.
To configure 'minicom' for a particular port, run it with the '-s'
option.  In the 'serial port setup' menu option, set the serial device to
the required   ISI port device (for example,  '/dev/ttyM1a' for the first
port on the first card).  Save the configuration for a particular port
using the 'save setup as' menu  option as, for example, '1a' for the port /
dev/ttyM1a. To connect to the port /dev/ttyM1a using minicom the
next time, '
minicom 1a
' needs to be executed.
LINUX: TTY Devices Created by the Drivers:
Device files corresponding to ports on the ISI card are created in
the /dev folder.  Use 
ttyMxy
 
for normal ports and 
cumxy
 
for
corresponding callout ports.  Normal ports (ttyM) are configured for
dial-in connections.  Callout ports (cum) are used for dial-out
connections.