HP (Hewlett-Packard) HP 16500C Manuel D’Utilisation
To capture a write of known bad data to a particular
variable
variable
The trigger specification ANDs the bad data on the data bus, write
transaction on the status bus, and address of the variable on the address bus.
transaction on the status bus, and address of the variable on the address bus.
1
Select the state analyzer Trigger menu.
2
Define the terms BAD_DATA, WRITE, and VAR_ADDR to represent
the bad data value, write status, and the address of the variable.
the bad data value, write status, and the address of the variable.
3
Under State Sequence Levels, enter the following sequence
specification:
specification:
•
While storing “anystate” TRIGGER on “BAD_DATA
•
WRITE
•
VAR_ADDR” one time (you use the Combination trigger term to do this)
•
Store “anystate”
Capturing a Bad Write to a Variable
Triggering
To capture a write of known bad data to a particular variable
To capture a write of known bad data to a particular variable
1–10