Fujitsu B23Q8YA-G-02-F Manuel D’Utilisation

Page de 52
 
 
 
   
22 
-  If you execute ndd command repeatedly, fjgi interface performance may drop.   
-  The values of link_speed, link_mode, autonego, flow_control are effective, only when link_status 
= 1. If link_status = 0, these values are invalid.   
-  The values of lp_10fdx_cap, lp_10hdx_cap, lp_100fdx_cap, lp_100hdx_cap, lp_1000fdx_cap, 
lp_1000hdx_cap, lp_pauseTX, lp_pauseRX, lp_autoneg_cap are effective, only when 
communication is done without Autonegation or Autonegation has not been established.   
-  The values set by ndd command are invalid after reboot.   
-  Since a setup of the operation mode by the ndd command becomes effective per physical interface, 
when IPv4/IPv6 interface, SNA/FNA interface or the VLAN interface is being used, those are also 
changed simultaneously. 
4.3.2.4  Changing the setting of FCode 
This section explains how to change the communication mode settings of FCode with examples. 
If using PCI card (PW008GE4/PW008GE5/PW008QG1), please refer to the User’s guide attached with PCI 
card. 
 
It is needed when don't use autonegotiation for speed/duplex/flowcontrol or connecting partner cannot 
support autonegotiation. 
 
[FCode Force mode (Speed Fixed and disable autonegotiation) setting method] 
Search for the device path of 'FJSV' or 'pwga' in the OK prompt screen. 
Example 
ok show-nets <Return> 
a) /pci@83,2000/FJSV,pwga@1 
b) /pci@1f,4000/network@1,1 
q) NO SELECTION 
Enter Selection, q to quit: 
In this example, a) is the device path of the pwga (secondary LAN port) 
 
With the following command, the device is specified. 
ok cd /pci@83,2000/FJSV,pwga@1 <Return> 
 
Implement the following commands, it will change from AutoNegotiation mode to Force mode. 
This setting is invalid during OBP (Open Boot Prom). PW008GE4 (1000BASE-SX) can use only 3) speed 
setting commands.   
 
1) Role setting commands   
slave-mode  (slave) 
 
2) Half Duplex setting commands   
half-duplex  (Half  Duplex) 
 
3) Speed setting commands 
transfer-speed=100    (Force  Speed:  100Mbps) 
transfer-speed=10     (Force  Speed:  10Mbps) 
 
With the following command, the device setting information is displayed. 
ok  .prp <Return> 
 
Example: PRIMEPOWER 450