Fujitsu 154V Manuel D’Utilisation

Page de 60
2-4       HIGH VOLTAGE WARNING
 
 
 
Operation of monitor outside of cabinet or with back removed may cause a serious shock hazard. Work on this model should only be 
performed by those who are thoroughly familiar with precautions necessary when working on high voltage equipment.
 
 
 
Exercise care when servicing this chassis with power applied. Many B plus and high voltage terminals are exposed which, if carelessly 
contacted, can cause serious shock or result in damage to the chassis. Maintain interconnecting ground lead connections between chassis 
and picture tube dag when operating chassis.
 
 
 
Certain HV failures can increase X-ray radiation. Monitor should not be operated with HV
 levels exceeding 
the specified rating for 
the chassis type. The maximum operating HV specified for the chassis used in this monitor is
 
 
 
24.5KV  ±  1KV
 
 
 
with a line voltage of 120/240 VAC. Higher voltage may also increase possibility of failure in HV supply.
 
 
 
It is important to maintain specified values of all components in the horizontal and high voltage circuits and anywhere else in the monitor 
that could cause a rise in high voltage or operating supply voltages. No changes should be made to the original design of the monitor. 
Components   shown   in   the   shaded   areas   on   the   schematic   should   be   replaced with exact factory   replacement   parts.   The   use   of 
unauthorized substitute parts may create a shock, fire or other hazard.
 
 
 
To determine the presence of high voltage, use an accurate, high impedance, HV meter connected between second anode lead and CRT 
dag grounding device. When servicing the High Voltage System, remove static charge from it by connecting a 10K ohm resistor in series 
with an insulated wire (such as a test probe) between picture tube dag and 2nd anode lead.(AC line cord disconnected from AC power 
outlet.)
 
 
 
The picture tube used in this monitor employs integral implosion protection. Replace with tube of the same type number for continue 
safety. Do not lift picture tube by the neck. Handle the picture tube only after discharging the high voltage completely.
 
 
 
 
Page 6 of 59
4V SERIES MANUAL
05.06.2002
file://D:\PC%20AOC\SERVICE%20MANUAL\FSC\154V\154V-C551.htm