Omega 1002 Manuel D’Utilisation

Page de 48
 
 
   For OME-PCI-1002H: 
[Bit1,Bit0] 
[0 0] 
[0 1] 
[1 0] 
[1 1] 
Gain 1  10 100 
1000 
 
3.   These registers are set to 0 after power-on or a hardware reset signal. 
 
 
 
3.2.2.8  The General Control Register 
 
The general control register (18h) is used to control the add-on interrupt 
source and the A/D trigger method. The format of this register is: 
 
Bit4-2 Bit 
1-0 
Interrupt source 
selection register 
A/D trigger method 
selection register 
 
3.2.2.8.1  Interrupt Source Selection 
 
There are four interrupt sources selectable for the OME-PCI-1002 (see 
section 1.4.4).  
 
[Bit4,Bit3,Bit2] Description 
[ 0, 0, 0 ] 
 No interrupt source, disable all interrupts. 
[ 0, 0, 1 ] 
 Interrupt after A/D conversion completes. 
[ 0, 1, 0 ] 
 Interrupt after 8254 timer 0 falling. 
[ 0, 1, 1 ] 
 Interrupt after external trigger falling. 
[ 1, 0, 0 ] 
 Interrupt after 8254 timer 1 falling. 
Others 
 No interrupt source, disable all interrupts. 
 
Note: Bit 3-3 of general control register is set to 0 after a hardware reset. 
 
 
 
 
33