3.
Switch Settings
Switch Settings
SWITCH NAME
SWITCH 
NUMBER
SETTING 
POSITION
FUNCTION
CHECK
SENS
(Rotary SW)
Note 1
F
Set the switch to match the AP Number (04-15) as set by
CM05.
~
 3
Not used
MB (Toggle SW)
Note 2
UP
For make-busy
For normal operation
SW0, SW10
(Dip SW)
1
For terminating the transmitting side
of channels B1 and B2 with 100 ohms.
OFF
To remove the terminating resistor on
the transmitting side of channels B1
and B2.
2
For terminating the receiving side of
channels B1 and B2 with 100 ohms.
OFF
To remove the terminating resistor on
the receiving side of channels B1 and
B2.
0
AP No.
04
05
06
07
08
09
10
11
12
13
14
15
SW No.
4
5
6
7
8
9
A
B
C
D
E
F
ON
DOWN
1
ON
2
ON
ON