6  Pre-Installation Masonry Fireplace Requirements 
 
The  masonry  fireplace  must  meet  the  minimum  requirements  found  in  the  building  code 
enforced  locally,  or  the  equivalent  for  a  safe  installation.  Contact  your  local  Building 
Inspector for requirements in your area.  An inspection of the fireplace should include the 
following: 
1.  CONDITION OF THE FIREPLACE AND CHIMNEY: 
The  masonry  fireplace  and  chimney  should  be  inspected  prior  to  installation,  to 
determine that they are free from cracks, loose mortar, creosote deposits, blockage, or 
other  signs  of  deterioration.    If  evidence  of  deterioration  is  noted,  the  fireplace  or 
chimney should be upgraded and/or cleaned prior to installation. 
Masonry  or  steel,  including  the  damper  plate,  may  be  removed  from  the  smoke  shelf 
and  adjacent  damper  frame  if  necessary  to  accommodate  the  insert’s  chimney  liner, 
provided that their removal will not weaken the structure of the fireplace and chimney, 
and will not reduce protection for combustible materials to less than that required by the 
building code. 
2.  INSTALLATION  INTO  AN  EXISTING  FACTORY-BUILT  ZERO-CLEARANCE 
FIREPLACE: 
It  is  possible  to  install  a  wood  insert  into  an  existing  factory-built  zero-clearance 
fireplace.  However, there currently exists no UL or ULC standard specific to that type 
of installation.  The factory-built  zero clearance fireplace must be listed; that is, safety 
certified by an accredited certification agency.  It must be suitable for use with solid fuel 
and  nothing  in  the  owner’s  manual  must  specifically  prohibit  the  installation  of  a 
fireplace insert. When in doubt, check with the fireplace manufacturer.  The installation 
of the zero-clearance fireplace MUST be thoroughly inspected by a qualified person to 
ensure  that  it  still  meets  the  manufacturer’s  specifications.  The  chimney  must  be  at 
least  1"  (25  mm)  larger  in  diameter than  the stainless  steel  liner that  will  run  from  the 
insert flue collar to the top of the chimney termination. 
Never remove parts intended to insulate the zero-clearance fireplace from combustible 
material. Only readily detachable parts that are easily replaced, such as damper parts, 
screens,  and  doors,  are  to  be  removed  from  the  fireplace.    These  parts  should  be 
stored  and  available  for  reinstallation  if  the  insert  is  ever  removed.    Removal  of  any 
parts which render the fireplace unfit for use with solid fuel requires the fireplace to be 
permanently  labeled by  the  installer  as  being  no  longer  suitable for  solid  fuel  until  the 
removed  parts  are  replaced  and  the  fireplace  is  restored  to  its  original  certified 
condition.  Also,  any  air  vents,  grilles,  or  louvers  that  allow  air  circulation  around  the 
fireplace must not be removed or blocked.