Motorola MVME956AC Manuel D’Utilisation

Page de 60
2-4
Computer Group Literature Center Web Site
Chassis Mount Options
2
Rack Mounting Option
The MVME956AC can be mounted, along with other equipment, in a 
standard 19-inch RETMA (or equivalent) rack. If the chassis is equipped 
with the benchtop cover kit, you must first remove it.
Cover Kit Removal
1. The top and side panels are attached with ball stud pop-on, pop-off 
catches. Remove the top panel by grasping the panel at the edges 
and lifting it straight up from the chassis. 
2. Remove the side panels by firmly grasping each panel and pulling it 
straight out from the chassis. 
3. Remove the ball studs from the top and sides of the chassis.
4. Remove the disk drive cover from the front opening.
To rack mount the MVME956AC unit, you must use the optional slide 
mounting kit, MVME946RKMT. Be sure to observe and follow the special 
cooling requirements explained in 
To rack-mount an MVME956AC chassis, follow the procedure below. 
1. Install the two chassis slide sections as shown in using the binder-
head screws that came in the kit. The right and left sections are 
identical. 
2. Determine where you will mount the chassis in the rack and how 
much space is required for mounting. Install the rack slide rails in 
the equipment rack using the binder-head screws and barnuts 
supplied. The chassis can now be installed in the rack. 
Note: The rack slide rails (18-5/8 inches) must coincide with that of 
the chassis slide rails. 
3. Align the chassis slide sections with the two rack-mounted slide 
sections.
4. While depressing the loc/stop buttons on the chassis slide sections, 
slide the chassis into the rack. Adjust the slide mounting hardware 
until the chassis slides in and out smoothly.