Novatel OM-20000077 Manuel D’Utilisation

Page de 87
22
SUPERSTAR II User Manual Rev 3
Chapter 3
Installation
3.3.3
Data Link
The data link for differential operation must operate at a minimal rate of 9600 bps.
3.3.4
Base Station and Rover Units Separation
The operational range of carrier-phase differential measurements is limited to about 20 km, after which 
significant accuracy degradation can occur. If your application requires greater separations, your own base 
station network must be established.
3.4
Connectors and Connector Pins Assignment
The receiver has two standard connectors. 
J1 is a 20-pin connector for general input/output interfaces and power input
J2 is a MCX type RF connector. 
The minimum number of connections on J1 required for the system to operate is shown in Table 2.
 Table 2: Minimum J1 Connections
If DGPS corrections are required for the application, the SUPERSTAR II can receive them on COM2:
If an active antenna is used:
CAUTION: You should use a current-limiting power source. The maximum current is 40 mA.
3.4.1
J1 Interface and Power Connector
The SUPERSTAR II connector is a 2mm straight 2x10 pin header:
Suggested supplier: 
Samtec
On-Board connector:
TMM-110-03-T-D.
Signal Name
J1 Pin #
Description
VCC
2
Primary power (3.3V or 5.0V  -0.5 V/+0.25 V)
GND
10, 13, 16 & 18
Ground
TX_No_1
11
Serial port Tx #1
RX_No_1
12
Serial port Rx #1
Signal Name
J1 Pin #
Description
RX_No_2
15
Serial port Rx #2
Signal Name
J1 Pin #
Description
PREAMP
1
Power for active antenna (40 mA max)