Electrical Characteristics 
Over the Operating Range (continued)
Parameter
Description
Test Conditions
7C144-35
7C145-35
7C144-55
7C145-55
Unit
Min
Max
Min
Max
V
OH
Output HIGH Voltage
V
CC
 = Min., I
OH
 = 
−4.0 mA
2.4
2.4
V
V
OL
Output LOW Voltage
V
CC
 = Min., I
OL
 = 4.0 mA
0.4
0.4
V
V
IH
Input HIGH Voltage
2.2
2.2
V
V
IL
Input LOW Voltage
0.8
0.8
V
I
IX
Input Leakage Current
GND < V
I
 < V
CC
−10
+10
−10
+10
μA
I
OZ
Output Leakage Current
Outputs Disabled, GND < V
O
 < V
CC
−10
+10
−10
+10
μA
I
CC
Operating Current
V
CC
 = Max., I
OUT
 = 0 mA
Outputs Disabled
Commercial
160
160
mA
Industrial
180
180
I
SB1
Standby Current
(Both Ports TTL Levels)
CE
L
 and CE
R
 > V
IH
,
f = f
MAX
Commercial
30
30
mA
Industrial
40
40
I
SB2
Standby Current
(One Port TTL Level)
CE
L
 or CE
R
 > V
IH
,
f = f
MAX
Commercial
100
100
mA
Industrial
110
110
I
SB3
Standby Current
(Both Ports CMOS Levels)
Both Ports 
CE and CE
R
 > V
CC
 – 0.2V,
V
IN
 > V
CC
 – 0.2V
or V
IN
 < 0.2V, f = 0
Commercial
15
15
mA
Industrial
30
30
I
SB4
Standby Current
(One Port CMOS Level)
One Port
CE
L
 or CE
R
 > V
CC
 – 0.2V,
V
IN
 > V
CC
 – 0.2V or 
V
IN
 < 0.2V, Active
Port Outputs, f = f
MAX
Commercial
90
90
mA
Industrial
100
100
Capacitance
Parameter
Description
Test Conditions
Max.
Unit
C
IN
Input Capacitance
T
A
 = 25
°C, f = 1 MHz,
V
CC
 = 5.0V
10
pF
C
OUT
Output Capacitance
15
pF
Note:
8. Tested initially and after any design or process changes that may affect these parameters.