Samsung C8274X Manuel D’Utilisation

Page de 324
S3C8275X/F8275X/C8278X/F8278X/C8274X/F8274X  
 
CONTROL 
REGISTER 
  
4-41 
SIOCON
 — SIO Control Register 
E1H 
Set 1, Bank 0 
Bit 
Identifier 
.7 .6 .5 .4 .3 .2 .1 .0 
Reset Value 
0 0 0 0 0 0 0 0 
Read/Write 
R/W R/W R/W R/W R/W R/W R/W R/W 
Addressing Mode 
Register addressing mode only 
 
.7 
SIO Shift Clock Selection Bit 
 
Internal clock (P.S clock) 
 
External clock (SCK) 
 
.6 
Data Direction Control Bit 
 
0 MSB-first 
mode 
 
1 LSB-first 
mode 
 
.5 
SIO Mode Selection Bit 
 
0 Receive-only 
mode 
 
1 Transmit/receive 
mode 
 
.4 
Shift Clock Edge Selection Bit 
 
Tx at falling edges, Rx at rising edges 
 
Tx at rising edges, Rx at falling edges 
 
 
.3 
SIO Counter Clear and Shift Start Bit 
 
0 No 
action 
 
Clear 3-bit counter and start shifting 
 
.2 
SIO Shift Operation Enable Bit 
 
Disable shifter and clock counter 
 
Enable shifter and clock counter 
 
.1 
SIO Interrupt Enable Bit 
 
Disable SIO interrupt 
 
Enable SIO interrupt 
 
.0 
SIO Interrupt Pending Bit 
 
No interrupt pending (when read), Clear pending bit (when write) 
 
Interrupt is pending (when read)