Samsung C8274X Manuel D’Utilisation

Page de 324
S3C8275X/F8275X/C8278X/F8278X/C8274X/F8274X  
 
CONTROL 
REGISTER 
  
4-45 
TACON
 — Timer 1/A Control Register 
E6H 
Set 1, Bank 1 
Bit 
Identifier 
.7 .6 .5 .4 .3 .2 .1 .0 
Reset Value 
0 0 0 0 0 0 0 0 
Read/Write 
R/W R/W R/W R/W R/W R/W R/W R/W 
Addressing Mode 
Register addressing mode only 
 
.7 
Timer 1 Operating Mode Selection Bit 
 
Two 8-bit timers mode (timer A/B) 
 
One 16-bit timer mode (timer 1) 
 
 
.6–.4 
Timer 1/A Clock Selection Bits 
 
0 0 0 
fxx/512 
 
0 0 1 
fxx/256 
 
0 1 0 
fxx/64 
 
0 1 1 
fxx/8 
 
1 0 0 
fxx 
(system 
clock) 
 
1 0 1 
fxt 
(sub 
clock) 
 
1 1 0 
T1CLK 
(external 
clock) 
 
1 1 1 
Not 
available 
 
.3 
Timer 1/A Counter Clear Bit 
 
0 No 
effect 
 
Clear the timer 1/A counter (when write, automatically cleared to "0" after being 
cleared basic timer counter) 
 
.2 
Timer 1/A Counter Operating Enable Bit 
 
Disable counting operation 
 
Enable counting operation 
 
.1 
Timer 1/A Interrupt Enable Bit 
 
0 Disable 
interrupt 
 
1 Enable 
interrupt 
 
.0 
Timer 1/A Interrupt Pending Bit  
 
No interrupt pending (when read), clear pending bit (when write) 
 
Interrupt is pending (when read)