INSTRUCTION SET 
 
 
S3C8275X/F8275X/C8278X/F8278X/C8274X/F8274X 
6-6  
 
FLAGS REGISTER (FLAGS) 
The flags register FLAGS contains eight bits that describe the current status of CPU operations. Four of these 
bits, FLAGS.7
−FLAGS.4, can be tested and used with conditional jump instructions; two others FLAGS.3 and 
FLAGS.2 are used for BCD arithmetic.   
The FLAGS register also contains a bit to indicate the status of fast interrupt processing (FLAGS.1) and a bank 
address status bit (FLAGS.0) to indicate whether bank 0 or bank 1 is currently being addressed. FLAGS register 
can be set or reset by instructions as long as its outcome does not affect the flags, such as, Load instruction.   
Logical and Arithmetic instructions such as, AND, OR, XOR, ADD, and SUB can affect the Flags register. For 
example, the AND instruction updates the Zero, Sign and Overflow flags based on the outcome of the AND 
instruction. If the AND instruction uses the Flags register as the destination, then simultaneously, two write will 
occur to the Flags register producing an unpredictable result. 
System Flags Register (FLAGS)
D5H, Set 1, R/W
.7
.6
.5
.4
.3
.2
.1
.0
MSB
LSB
Bank address
status flag (BA)
Fast interrupt
status flag (FIS)
Half-carry flag (H)
Decimal adjust flag (D)
Carry flag (C)
Zero flag (Z)
Sign flag (S)
Overflow flag (V)
 