Samsung C8274X Manuel D’Utilisation

Page de 324
S3C8275X/F8275X/C8278X/F8278X/C8274X/F8274X 
 
 
SERIAL I/O INTERFACE 
  
14-3 
SIO PRE-SCALER REGISTER (SIOPS) 
The prescaler register for serial I/O interface module, SIOPS, is located at E3H in set 1, bank 0. 
The value stored in the SIO pre-scaler register, SIOPS, lets you determine the SIO clock rate (baud rate) as 
follows: 
Baud rate    = Input clock (fxx/4)/(Prescaler value + 1),    or SCK input clock. 
SIO Pre-scaler Register (SIOPS)
E3H, Set 1, Bank 0, R/W
.7
.6
.5
.4
.3
.2
.1
.0
MSB
LSB
Baud rate = (f
XX
/4)/(SIOPS + 1)
 
Figure 14-2. SIO Prescaler Register (SIOPS) 
SIO BLOCK DIAGRAM 
SIO INT
Pending
3-Bit Counter
Clear
SIOCON.0
fxx/2
SIOPS (E3H, set 1, bank 0)
SCK
SIOCON.7
SIOCON.1
(Interrupt Enable)
CLK
SI
SIOCON.3
Data Bus
SO
M
U
X
1/2
8-bit P.S.
8
8-Bit SIO Shift Buffer
(SIODATA, E2H, set 1, bank 0)
CLK
SIOCON.4
(Edge Select)
SIOCON.5
(Mode Select)
SIOCON.2
(Shift Enable)
SIOCON.6
(LSB/MSB First
Mode Select)
 
Figure 14-3. SIO Functional Block Diagram