Samsung C8274X Manuel D’Utilisation

Page de 324
BATTERY LEVEL DETECTOR   
 
 
S3C8275X/F8275X/C8278X/F8278X/C8274X/F8274X 
15-2 
 
BATTERY LEVEL DETECTOR CONTROL REGISTER (BLDCON) 
The bit 3 of BLDCON controls to run or disable the operation of Battery Level Detector. Basically this V
BLD
 is set 
as 2.2V by system reset and it can be changed in 3 kinds voltages by selecting Battery Level Detector Control 
Register (BLDCON). When you write 3-bit data value to BLDCON, an established resistor string is selected and 
the V
BLD
 is fixed in accordance with this resistor. Table 15-1 shows specific V
BLD
 of 3 levels.   
Battery Level Detector Control Register
F4H, Set 1, Bank 1, R/W, Reset : 00H
.7
.6
.5
.4
.3
.2
.1
.0
MSB
LSB
Not used
 +
   Comparator
Mux
BANDGAP
BLD Enable/Disable
BLD 
OUT
Bias
V
REF
V
IN
R
BLD
V
BLDREF
Resistor String
P2CONL.1-.0
V
BAT
NOTES:
1.    The reset value of BLDCON is #00H.
2.    V
REF
 is about 1 volt.
f
BLD
 
Figure 15-2. Battery Level Detect Circuit and Control Register 
Table 15-1. BLDCON Value and Detection Level 
BLDCON .2
.0 
V
BLD
 
0   0   0 
2.2 V 
1   0   1 
2.4 V 
0   1   1 
2.8 V 
Other values 
Not available