Promise Technology M310p Manuel D’Utilisation

Page de 262
Chapter 7: Technology Background
201
In the example above, there is a four-drive RAID 5 disk array and a global spare 
drive. Physical drives 1, 2, 3, and 4 belong to the disk array. Physical drive 5 
remains unconfigured. Physical drive 6 is a revertible spare drive.
If a physical drive fails in a disk array and there is a spare drive of adequate 
capacity available, the controller automatically rebuilds the array using the spare 
drive. In this example, physical drive 3 failed and the array is rebuilt using 
physical drive 6, the revertible spare drive.
When the rebuild is complete, the spare drive has replaced the failed drive. In this 
example, failed drive 3 was replaced by spare drive 6. The disk array now 
consists of physical drives 1, 2, 4, and 6.
There is no spare drive at this moment. Even if physical drive 5 is of adequate 
capacity, it has not been designated as a spare, therefore the controller cannot 
use it as a spare.