Lucent Technologies R5SI Manuel D’Utilisation

Page de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-74
ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon Analog Line) 
10
Station Status and Translation Audits and 
Updates Test (#36)
This test updates the analog port’s message lamp state (if it has one) and 
translations (such as station type, dial type, network connection) with information 
kept in the software. The software is updated with the switchhook state reported 
by the port processor. When the ringer is in the off state, this test also turns off 
the station’s ringer to prevent constant ringing caused by defective hardware.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board). This could be 
due to incorrect translations, no board is inserted, an incorrect board is 
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the 
list 
config
 command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the 
busyout board
 command.
3. Issue the 
reset board
 command.
4. Issue the 
release busy board
 command.
5. Issue the 
test board long
 command. This should re-establish the 
linkage between the internal ID and the port. If this is not the case, 
dispatch to check to ensure that there is a valid board inserted.
Table 10-28.
TEST #35 Battery Feed Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page