Fujitsu FR81S Manuel D’Utilisation
CHAPTER 44: 12-BIT A/D CONVERTER
4. Registers
FUJITSU SEMICONDUCTOR LIMITED
CHAPTER
: 12-BIT A/D CONVERTER
FUJITSU SEMICONDUCTOR CONFIDENTIAL
42
4.2.9. Range Compare Control Status Register: ADRCCS0 to
ADRCCS47
The bit configuration of the range compare control status register is shown.
The range compare control status register (ADRCCS) confirms the instruction of the continuous detection
count and the state of the continuous detection count. And, this register selects inside/outside the range
confirmation, range comparison interrupt request enable/disable, range comparison execution
enable/disable, and upper and lower bound threshold.
ADRCCS0 to ADRCCS31: Address 141C
H
to 143B
H
(Access: Byte, Half-word,
Word)
ADRCCS32 to ADRCCS47: Address 1588
H
to 1597
H
(Access: Byte, Half-word,
Word)
bit7
bit6
bit5
bit4
bit3
bit2
bit1
bit0
RCOCD2 RCOCD1 RCOCD0 RCOIRS
RCOIE
RCOE
RCOTS1 RCOTS0
Initial value
0
0
0
0
0
0
0
0
Attribute
R/W
R/W
R/W
R/W
R/W
R/W
R/W
RW
[bit7 to bit5] RCOCD2 to RCOCD0 : Continuous detection count specification and state indicate bit
RCOCD2
to
RCOCD0
Explanation
Read by a other than
read-modify-write (RMW) instruction
Read by a read-modify-write
(RMW) instruction or writing
"000
B
"
State of continuous detection : 0 time
Setting disable
"001
B
"
State of continuous detection : 1 time
Continuous detection is specified 1 time
"010
B
"
State of continuous detection : 2 times
Continuous detection is specified 2 times
"011
B
"
State of continuous detection : 3 times
Continuous detection is specified 3 times
"100
B
"
State of continuous detection : 4 times
Continuous detection is specified 4 times
"101
B
"
State of continuous detection : 5 times
Continuous detection is specified 5 times
"110
B
"
State of continuous detection : 6 times
Continuous detection is specified 6 times
"111
B
"
State of continuous detection : 7 times
Continuous detection is specified 7 times
These bits show the specification of the continuous detection count of the range comparison result and
the state of the continuous detection count.
When the range comparison result reaches the continuous count specification value, "1" is set to the
range comparison interrupt factor flag bit of the corresponding activation channel (ADRCIF.RCINT n).
Moreover, continuous detection stops by the continuous count specification value.
When reading other than read-modify-write (RMW) instruction, state of continuous detection is read.
When read-modify-write (RMW) instruction is read, the writing value (continuous count instruction
value) is read.
MB91520 Series
MN705-00010-1v0-E
1845