Fujitsu C122-E177-01EN Manuel D’Utilisation

Page de 512
MMB Web-UI (Web User Interface) Operations 
 
Items 
Description 
· 
Not-present 
Vendor 
The vender of a physical drive is displayed. 
Model 
The model name of a physical drive is displayed. 
Capacity 
The capacity of a physical drive is displayed. 
RAID Card# 
The slot number of RAID Card that connects a physical drive is displayed. 
Logical Drives 
Sensor# 
The sensor number of a logical drive is displayed. 
Status 
The state of a logical drive is displayed. 
Raid Level 
The RAID level of a logical drive is displayed. 
Physical Drives 
assignment 
The slot number of a physical drive that composes a logical drive is displayed. 
Missing drives count 
The number of physical drives missed to compose a logical drive at the RAID level 
is displayed. 
RAID Action Progress 
Drive Type 
The drive type that the RAID action is executed is displayed. 
· 
Physical : Hardware RAID 
· 
Logical  : Software RAID 
Slot#/Sensor# 
Slot# from which the RAID action is executed is shown when Drive Type is 
Physical, and Sensor# from which the RAID action is executed is shown when 
Drive Type is Logical. 
Action 
The RAID action under execution is displayed. 
· 
Rebuilding : It is shown for a physical drive to execute the rebuild of the RAID 
drive. 
· 
MDC Running : It is shown for a logical drive to execute MDC(Make Data 
Consistent). 
Progress 
The progress rate of the RAID action under execution is displayed by the 
percentage. 
Estimated time 
remaining (hh:mm:ss) 
The remainder time that will be expected by the time the RAID action under 
execution is completed is displayed. 
Voltage 
Sensor 
Displays the Voltage sensor type. 
12V_DU_SLOT0 
12V_DU_SLOT1 
Voltage 
Displays the current power voltage. 
Threshold 
Warning 
(Low/High) 
Lower and upper limits of the warning-level voltage.  
 
Displays “ – ”, when the threshold is not set. 
Displays the power voltage in the last two decimal places. 
Critical 
(Low/High) 
Lower and upper limits of the critical-level voltage. 
 
Displays “ – ”, when the threshold is not set. 
Displays the power voltage in the last two decimal places. 
 
TABLE 1.48 Buttons on [DU#x] Window 
Button 
Description 
Status Clear 
Clears the error message of the disk unit 
 
When the [Status Clear] button is clicked, the error status of the disk unit will be cleared and it can be 
specified so that the disk unit can be used again at the time of the next reboot. When an error is detected 
again at the time of re-boot, the error status of the disk unit would be recorded again. 
 
(1)  Menu Operation 
 [System] – [DU] – [DU#x] 
 
(2)  Window Operations