Fujitsu C122-E177-01EN Manuel D’Utilisation

Page de 512
MMB Web-UI (Web User Interface) Operations 
 
The Reserved SB cannot be set when TPM function is used for the Home SB. 
The Reserved SB cannot be set though Fixed I/O Mode is specified in the Partition. 
 
When mounting conditions are not fulfilled, a message is displayed and Reserved SB cannot be set. 
 
For a partition that is set to Mirror mode, if you attempt to set an SB with a DIMM configuration that does not 
satisfy the Mirror mode requirements as a Reserved SB for a partition that is set to Mirror mode, a 
confirmation dialog box appears. A warning message stating that Mirror Mode is cancelled while shifting to 
Reserved SB is displayed in the dialog box for confirmation and whether to continue with the Reserved SB 
settings is confirmed. 
 
When several Reserved SBs are registered in one Partition, they operate as Reserved SBs in ascending 
order of SB number. 
 
TABLE 1.72 Display Items and Set Items of [Reserved SB Configuration] Window 
Items 
Description 
Displays number that identifies the Partition.  
 
Reserved:  Reserved SB 
 
Free:  Free SB 
Partition Name 
Displays name given to Partition. 
Power Status 
Displays the power status of the partition 
 
On 
 
Standby 
Mirror Mode (setting) 
Displays the setting value of Mirror Mode corresponding to the Partition. 
 
Enable:  Mirror Mode is set 
 
Disable:  Mirror Mode is not set 
SB 
Displays the Partition to which the SB belongs. 
The check box to register the SB as a Reserved SB in the Partition of the 
corresponding line is displayed in the cell which corresponds to Reserved SB or 
Free SB. 
 
TABLE 1.73  [Reserved SB Configuration] Window Buttons 
Buttons 
Description 
Apply 
If “[Apply]” button is clicked, it is defined as Reserved SB. 
Cancel 
If “[Cancel]” button is clicked, it returns to the original state without being defined as a Reserved 
SB. 
 
(1)  Menu Operation 
[Partition] - [Reserved SB Configuration] 
 
(2)  Window Operations 
1. 
The check box of Partition intended for Reserved SB is set to ON. 
2. 
Click the [Apply] button. 
 
[Message] 
 
This section describes the messages to be displayed on this window. 
Message Number 
Message 
E_00098 
Failed to get the Replacement Condition  
E_00100 
Failed to set the Replacement Condition  
E_00113 
Unable to register the specified SB#%aa as a Reserved SB due to CPU mismatch 
between SBs.  
E_00114 
The specified SB#%aa cannot be registered as a Reserved SB.  
I_00223 
Unable to change the specified SB(s) because the partition including the specified 
SB(s) is under maintenance.  
E_00419 
Unable to register the specified SB#%s as a Reserved SB due to unsupported CPU 
configuration.  
E_00420 
Unable to register the specified SB#%s as a Reserved SB because the DIMM does