MMB Web-UI (Web User Interface) Operations 
 
Message Number 
Message 
E_00142 
Unable to power off the System. 
E_00002 
Command Failed 
E_00144 
Unable to power off/on the System. 
E_00145 
Unable to reset the System. 
E_00146 
Unable to generate an NMI interrupt in the System. 
E_00143 
Unable to forcibly power off the System. 
E_00091 
Force Power Off Delay setting failed. 
E_00xxx 
Unable to power on the system due to CPU mismatch between SBs. 
E_00154 
Unable to power on due to mismatch between supply voltage and input voltage. 
I_00151 
Unable to control system power because maintenance is in progress. 
Release maintenance mode first. 
E_00xxx 
Unable to power on the system due to CPU composition abnormal. 
E_00xxx 
Unable to power on the system due to DIMM composition abnormal. 
E_00xxx 
Unable to power on the system due to DIMM does not satisfy requirements of Mirror 
Mode. 
W_00504 
The Power On failed, because of switching the Home SB. 
Please execute it after a while again. 
 
 
E_00xxx 
Unable to power on the system due to abnormal SB composition. 
 
For details on the messages displayed on the window, see 
PRIMEQUEST 2000 Series Message Reference
 
(C122-E178EN). 
 
 
1.7.8  [Schedule] Menu 
The [Schedule] menu has the  [Schedule Control] and [Schedule List] windows. This section describes the 
windows and the operation. 
 
Note 
 
As mentioned below, there may be a delay in the time recorded in SEL compared to the time reserved for 
scheduled operations. 
 
 
After checking the configuration and after performing the start up preparation process, it takes some 
time until the power is ON. In this case, the SEL display is delayed about from six seconds up to 8 
seconds than the time reserved for the scheduled operations. 
 
The shutdown instructions from MMB to OPERATING SYSTEM take certain time from the set time. 
However, the following interval times may be changed under the various conditions like setting and the 
configuration. 
 
Interval time until shutdown instructions reaches OS from MMB. 
 
Interval time until MMB notifies SEL begin shutdown after OS begins shutdown. 
 
Even if the [Power on Delay] is 0 seconds, it takes about 30 seconds ~ 70 seconds from starting the 
power on up to the reset. 
 
  [Schedule Control] window 
In the [Schedule Control] window, the setting related to the schedule can be set for system.