Fujitsu C122-E177-01EN Manuel D’Utilisation

Page de 512
MMB Web-UI (Web User Interface) Operations 
 
Items 
Description 
Manual(C122-E175EN) 
Device ID 
Displays the Device ID of the PCI Card. 
Remarks: 
ID uniquely allocated in device of manufacturer. 
For details of the ID, see the PRIMEQUEST 2000 Series Administration 
Manual(C122-E175EN) 
PCIeSW 
PCIeSW 
Displays the number of PCIeSW. 
Status 
Displays the status of PCIeSW. 
 
OK 
 
Warning  
 
Failed 
PCIeSW#1 
Same as PCIeSW#0 
Voltage 
Voltage 
Sensor 
Displays the Voltage sensor type. 
P1.8VL(*1) 
P1.0VL(*1) 
P2.5VL(*2) 
P1.2VL(*2) 
P0.8VL(*2) 
P0.67VL(*2) 
P3.3V(*3) 
P1.8V_PCIEX#0(*1) 
P1.8V_PCIEX#1(*1) 
P1.8V(*2) 
P0.9V_PCIEX#0(*3) 
P0.9V_PCIEX#1(*3) 
 
*1: IOUL,*2: IOUF,*3: IOUL/IOUF commonness 
Voltage 
Displays the current power voltage. 
Threshold 
Warning 
(Low/High) 
Lower and upper limits of the warning-level voltage.  
 
Displays “ – ”, when the threshold is not set. 
Displays the power voltage in the last two decimal places. 
Critical 
(Low/High) 
Lower and upper limits of the critical-level voltage. 
 
Displays “ – ”, when the threshold is not set. 
Displays the power voltage in the last two decimal places. 
 
TABLE 1.162 Button of [IOB#x] Screen 
Buttons 
Description 
Status Clear 
Clears the error status of IOU#x 
 
 
1.7.16 [DU] Menu 
As for the display, the operation is the same as the PRIMEQUEST 2400E/2800E model. Refer to chapter 