Fujitsu C122-E177-01EN Manuel D’Utilisation

Page de 512
MMB CLI (Command Line Interface) Operations 
 
(1)  Input format 
 
set telnet [enable | disable] 
 
(2)  Option  
None 
 
(3)  Usage example 
None 
 
(4)  Message 
The following table lists the messages which are displayed in this CLI. 
 
For details of the messages, see the PRIMEQUEST 2000 Series Message Reference (C122-E178EN). 
 
Unable to execute this command on a standby MMB. 
 
 
2.2.34 set telnet_port
 
Sets the port which receives the telnet connection. Default setting is 23. 
 
Port numbers which can be set are 23, 1024~65535. 
 
  Privilege: Administrator 
 
(1)  Input format 
 
set telnet_port <port> 
 
(2)  Option  
None 
 
(3)  Usage example 
None 
 
(4)  Message 
The following table lists the messages which are displayed in this CLI. 
 
For details of the messages, see the PRIMEQUEST 2000 Series Message Reference (C122-E178EN). 
 
The specified port number is invalid. 
The specified port number is duplicated. 
Unable to execute this command on a standby MMB. 
 
 
2.2.35 set timezone
 
Set the Timezone. 
 
Remarks 
 
It is necessary to reset the time by using set date command after the time zone is set. 
 
  Privilege: Administrator 
 
(1)  Input format