Fujitsu C122-E177-01EN Manuel D’Utilisation

Page de 512
MMB CLI (Command Line Interface) Operations 
 
For details of the messages, see the PRIMEQUEST 2000 Series Message Reference (C122-E178EN). 
 
The specified partition number is invalid.  
The specified parameter is invalid.  
Unable to execute this command on a standby MMB.  
Failed to show partition name command.  
 
 
2.3.10 show partition memory_mirror_ras_mode
 
Displays Memory Mirror RAS Mode of the specified partition. 
 
mirror_keep: Sets the Mirror Keep Mode. 
capacity_keep: Sets the Capacity Keep mode. 
 
  Privilege: All 
 
(1)  Input format 
 
show partition memory_mirror_ras_mode <partition#> 
 
(2)  Option  
None 
 
(3)  Usage example 
 
Example: When Memory Mirror RAS Mode of partition 3 is displayed 
#show partition memory_mirror_ras_mode3 
current: mirror_keep 
setting: capacity_keep 
 
(4)  Message 
The following table lists the messages which are displayed in this CLI. 
 
For details of the messages, see the PRIMEQUEST 2000 Series Message Reference (C122-E178EN). 
 
The specified partition number is invalid.  
The specified parameter is invalid.  
Unable to execute this command on a standby MMB.  
Failed to execute %s command.  
Failed to execute show partition command.  
Partition#x is not defined.   
 
 
2.3.11 show partition memory_operation_mode
 
Displays the Memory Operation Mode of the specified partition. 
 
performance:  
Shows the Performance Mode 
normal:  
 
Shows the Normal Mode 
partial_mirror:  
Shows the Partial Mirror Mode 
full_mirror:    
Shows the Full Mirror Mode 
spare:  
 
Shows Spare Mode. 
 
  Privilege: All 
 
(1)  Input format