Fujitsu C122-E177-01EN Manuel D’Utilisation

Page de 512
MMB CLI (Command Line Interface) Operations 
 
spare:  
 
Shows Spare Mode. 
 
  Privilege: All 
 
(1)  Input format 
 
show memory_operation_mode 
 
(2)  Option  
None 
 
(3)  Usage example 
 
Example: When Memory Operation Mode of system is displayed 
#show memory_operation_mode 
current: normal 
setting: performance 
 
(4)  Message 
The following table lists the messages which are displayed in this CLI. 
 
For details of the messages, see the PRIMEQUEST 2000 Series Message Reference (C122-E178EN). 
 
The specified parameter is invalid.  
Failed to execute %s command.  
Failed to execute show memory_operation_mode command. 
System Configuration Failed. 
 
 
2.6.10 show memory_mirror_ras_mode
 
Displays Memory Mirror RAS Mode of the system. 
 
mirror_keep   
: Sets the Mirror Keep Mode. 
capacity_keep 
: Sets the Capacity Keep mode. 
 
  Privilege: All 
 
(1)  Input format 
 
show memory_mirror_ras_mode 
 
(2)  Option  
None 
 
(3)  Usage example 
 
Example: When Memory Mirror RAS Mode of system is displayed 
#show memory_mirror_ras_mode 
current: mirror_keep 
setting: capacity_keep 
 
(4)  Message 
The following table lists the messages which are displayed in this CLI. 
 
For details of the messages, see the PRIMEQUEST 2000 Series Message Reference (C122-E178EN). 
 
The specified parameter is invalid.