Fujitsu C122-E177-01EN Manuel D’Utilisation

Page de 512
Dynamic Reconfiguration Operation 
 
Device 
Target device.   e.g. IOUx, PCIex 
“x“ represents the slot number. 
Only one target can be specified at a time. 
--help 
Print the synopsis of add/rm subcommand 
 
 
5.1.2.4  Example 
e.g.  when you hot-add IOU3 
# /opt/FJSVdp-util/sbin/dp add IOU3 
 
 
5.1.3  Show slot status (slot subcommand) 
5.1.3.1  Synopsis 
/opt/FJSVdp-util/sbin/dp stat DeviceType 
 
 
5.1.3.2  Description 
This is the subcommand for displaying hot plug slot status of IOU or PCI Express card. 
The number displayed after the output device represents the slot number. 
 
The meaning of the state of IOU type is as follows: 
 
empty :  IOU is not assigned to the partition (OS)  
 
offline :  IOU is assigned to the partition, but the slot power is OFF. (IOU is disabled) 
 
online :  IOU is assigned to the partition and the slot power is ON. (IOU is enabled) 
 
The meaning of the state of pcie type is as follows: 
 
empty :There’s no PCI Express card on the slot 
 
offline :PCI Express card is on the slot, but the slot power is OFF. (PCIe is disabled) 
 
online :PCI Express card is on the slot, and the slot power is ON. (PCIe is enabled) 
 
 
5.1.3.3  Options 
Arguments 
Meaning 
Device Type 
Target device type.  e.g.  IOU, pcie 
Only one target can be specified at a time. 
--help 
Print the synopsis of stat subcommand 
 
 
5.1.3.4  Example 
e.g. When you hot-add PCI card to slot number 20 of PCI slot 
# /opt/FJSVdp-util/sbin/dp stat pcie 
pcie20: online 
pcie21: offline 