Appendix A List of Setting Items 
 
 
 
A.1.3 
Setting Items of [System Information] Window 
The following table lists the initial value and the value that can be set for setting items of [System 
Information] Window. 
 
TABLE A.3 Setting Items of [System Information] Window 
Setting 
items 
Initial value 
Value that can be set 
Remarks 
System 
Name 
“PRIMEQUEST” + 
Product Serial Number 
Maximum 64 characters 
can be entered [0-9], [a-z], 
[A-Z],! " # $ % & ' ( ) = - ^ ~ 
¥ @ ´ [ ] { } : ; * + ? < > . / _ 
|  
It is also used as System 
Name of SNMP 
Asset Tag 
None 
Maximum 32 characters 
can be entered (Only 
administrator privilege)  
 
 
 
A.1.4 
Setting items of [System Setup] Window 
The following table lists the initial value and the value that can be set of setting items of [System Setup] 
Window. 
 
TABLE A.4 Setting items of [System Setup] Window 
Setting 
Items 
Initial Value 
Value that can be set 
Remarks 
Power Feed 
Mode 
Single 
 Single 
 Dual 
 
Power 
Restoration 
Policy 
Restore 
 Always off 
 Always on 
 Restore  
 Schedule Sync  
 
Partition 
Power On 
Delay 
0 Seconds 
0 ~ 9999 Seconds 
 
Altitude 
Altitude < 1000 m 
 Altitude < 1000 m 
 1000 m <= Altitude < 
1500 m 
 1500 m <= Altitude < 
2000 m 
 2000 m <= Altitude 
Setting error for Altitude 
value can be 
±100 m.  
PSU 
Redundancy 
Non-Redundant (When 
Power Feed Mode is single) 
 Redundant 
 Non-redundant 
When Power Feed Mode is 
Dual, fix with Redundant 
Time Data of Specified 
Time. 
End 
Date/Time 
Last event 
 Last event 
 Specified Time 
When Specified Time is 
selected, End Time can be 
entered. 
Switch Last event and 
Specified time and maintain 
Time Data of Specified 
Time side. 
Number of 
events to 
display 
100 events 
0 or more, integer less than 
or equal to the denominator 
in the fraction displayed 
(Maximum 1000 events). 
The denominator of fraction 
which is displayed is a total 
number of registered 
events.