Emerson ATCA-9305 Manuel D’Utilisation

Page de 184
System Management:
 FRU LEDs
7-18
FRU LEDS
This section describes the front panel LEDs controlled by the IPMC and documents how to 
control each LED with the standard FRU LED commands. Reference the PICMG
®
 3.0 Revision 
2.0 AdvancedTCA
®
 Base Specification for more detailed information.
The ATCA-9305 has four Light-Emitting Diodes (LEDs) on the front panel. See 
 fo
their location.
Table 7-11:
FRU LEDs
Response Data
8
Present countdown value, lsbyte. The initial countdown value and 
present countdown values should match immediately after the 
countdown is initialized via a Set Watchdog Timer command and 
after a Reset Watchdog Timer has been executed.
Note that internal delays in the IPMC may require software to delay 
up to 100 ms before seeing the countdown value change and be 
reflected in the Get Watchdog Timer command.
9
Present countdown value, msbyte
LEDs:
ID 
(hex):
Reference 
Designator:
Description:
Hot 
Swap
00
CR57
The blue Hot Swap LED displays four states:
On—the board can be safely extracted
Off—the board is operating and not safe for 
extraction, 
Long blink—insertion is in progress
Short blink—requesting permission for 
extraction
OOS
01
CR54
The Out Of Service programmable LED 
controlled by the IPMI controller is either red 
(North America) or amber (Europe). When lit, 
this LED indicates the ATCA-9305 is in a failed 
state.
2
02
CR55
The green LED is user defined, but frequently is 
used as an In Service indicator. When used as an 
In Service indicator, a lit LED indicates that the 
ATCA-9305 is functioning properly.
3
03
CR56
The amber LED is user defined.
Type:
Byte:
Data Field: 
  (continued)