Management Processor Monitor:
 Basic Operation
9-3
BASIC OPERATION
The monitor performs various configuration tasks upon power-up or reset. This section 
describes the monitor operation during initialization of the ATCA-9305 board. The flow-
chart (see 
) illustrates the power-up and global reset sequence (bold text indicates 
environment variables).
Power-up/Reset Sequence
The ATCA-9305 monitor follows the boot sequence in 
 before auto-booting the oper-
ating system or application software. At power-up or board reset, the monitor performs 
hardware initialization, diagnostic routines, autoboot procedures, free memory initializa-
tion, and if necessary, invokes the command line. See 
 for the Cavium CN5860 pro-
cessor boot sequence. Se
 for default environment variables settings.
CHECKBOARD
get processor and bus speeds done
0x03
SDRAM_INIT
RAM / ECC init done
0x04
AFTER_RELOC
U-Boot relocated to RAM done
0x05
MISC_R
final init including Ethernet done
0x06
GONE_TO_PROMPT
0x00
LED Code:
Power-up Status:
LED Value: