Emerson ATCA-9305 Manuel D’Utilisation

Page de 184
Cavium Processor Complex:
 Cavium Monitor
3-7
Figure 3-4:
Power-up/Reset CN5860 Boot Sequence Flowchart
Diagnostic Tests During Power-up and Reset
The Cavium monitor diagnostic tests can be executed during power-up or invoked from the 
monitor’s command prompt. This is accomplished by changing the state of the monitor 
configuration parameters that define power-up and reset diagnostics mode. If the poweron-
diags
 parameter is set to “on”, the monitor invokes the diagnostic tests after a reset of the 
hardware. Results are displayed to the console including whether the test passed or failed.
POST Diagnostic Results
The ATCA-9305 Power-On Self-Test (POST) diagnostic results are stored as a 32-bit value in 
memory accessible by the management console at location 0x80080A6C. Each bit indicates 
the result of a specific test, so this field can store the results of up to 32 diagnostic tests. 
 assigns the bits to specific tests.
Power-up or Reset
Cavium Hardware
Wait for PCI load of U-boot
U-Boot Monitor
Default Board Initialization
U-Boot Monitor
Execute POST
U-Boot Monitor
Start Autoboot Sequence
(Boot Operating System)
Operating System Boot
Boot OS image 
according to