Emerson ATCA-9305 Manuel D’Utilisation

Page de 184
System Management:
 Standard Commands
7-9
dling, if it is necessary. If the Receive Message Queue is full, the ATCA-9305 IPMC rejects all 
requests coming to LUN 10 with the C0h (Node Busy) completion code and discards all 
responses coming to this LUN.
STANDARD COMMANDS
The Intelligent Peripheral Management Controller (IPMC) supports standard IPMI com-
mands to query board information and to control the behavior of the board. These com-
mands provide a means to: 
• identify the controller
• reset the controller
• return the controller’s self-test results
• read and write the controller’s SROMs
• read the temperature, voltage, and watchdog sensors
• get specific information, such as thresholds, for each sensor
• read and write the Field Replaceable Unit (FRU) data
• reserve and read the Sensor Data Record (SDR) repository
• configure event broadcasts
• bridge an IPMI request to the public IPMB and return the response
 lists the IPMI commands supported by the IPMC along with the hexadecimal values 
for each command’s Network Function Code (netFn), Logical Unit Number (LUN), and Com-
mand Code (Cmd):
Table 7-5:
IPMC IPMI Commands 
Command:
netFn:
LUN:
Cmd:
Set System Boot Options
Chassis
01, 01
07
Get System Boot Options
Chassis
01, 01
08
Set Event Receiver
Sensor/Event
04, 05
00
Get Event Receiver
Sensor/Event
04, 05
01
Platform Event (Event Message)
Sensor/Event
04, 05
02
Get Device SDR Information
Sensor/Event
04, 05
20
Get Device SDR
Sensor/Event
04, 05
21
Reserve Device SDR Repository
Sensor/Event
04, 05
22
Get Sensor Reading Factors
Sensor/Event
04, 05
23
Set Sensor Hysteresis
Sensor/Event
04, 05
24
Get Sensor Hysteresis
Sensor/Event
04, 05
25