5.5.2
Standard Status Codes
5.5.2.1
SEC Status Codes
Table 5-32 SEC Status Codes
Status Code
Description
0x0
Unused.
Progress Codes
0x1
Power on. Reset type detection (soft/hard).
0x2
AP initialization before microcode loading.
0x3
North Bridge initialization before microcode loading.
0x4
South Bridge initialization before microcode loading.
0x5
OEM initialization before microcode loading.
0x6
Microcode loading.
0x7
AP initialization after microcode loading.
0x8
North Bridge initialization after microcode loading.
0x9
South Bridge initialization after microcode loading.
0xA
OEM initialization after microcode loading.
0xB
Cache initialization.
SEC Error Codes
0xC - 0xD
Reserved for future AMI SEC error codes.
0xE
Microcode not found.
0xF