MIB Description
cgmControl
50
.1.1.2.1.6
dsx1LoopbackConfig
Loopback mode
Loopback mode disabled (1)
local (payload) loopback - Tx to Rx (2)
line loopback - Rx to Tx (3)
Default value is disabled (1).
r/w
.1.1.2.1.7
dsx1LineStatus
Current line status. This is a bit mask encoding the
following states:
following states:
-Bit 0 (value 0x01): Yellow alarm condition
-Bit 3 (value 0x08): Alarm condition
-Bit 5 (value 0x20): Loss of Frame condition
-Bit 6 (value 0x40): Loss of Signal condition
r
.1.1.2.1.10
bitsCurSsm
The last received synchronization status message
Not yet supported
r
.1.1.2.1.11
bitsSsmE1SaSelect
Selects on which Sa bit the E1 synchronization
status message is expected.
status message is expected.
Default value is (4).
Not yet supported
r/w
.1.1.2.1.13
bitsLiuJaEn
Enable jitter attenuator
Default value is disabled (0).
r/w
.1.1.2.1.14
bitsLiuJaDs
Jitter attenuator depth (32 or 128 bits)
Default value is 128 bits (0).
r/w
.1.1.2.1.16
bitsLiuEgl
Receive equalizer gain limit for T1 (-36/-15dB) and
E1 (-43/-12dB)
E1 (-43/-12dB)
Default value is (0).
r/w
.1.1.2.1.18
bitsLiuE1Lbo
E1 line build-out select in Ohm (without and with
high return loss)
high return loss)
120 Ohm (1)
120 Ohm with high return loss (3)
Default value is (1).
r/w
.1.1.2.1.19
bitsLiuT1Lbo
T1 line build-out select for DSX-1 application in
feet.
feet.
0 to 133 ft (0)
133 to 266 (1)
266 to 399 (2)
399 to 533 (3)
533 to 655 (4)
Default value is (0).
r/w
Table 5-4 cgmBitsTable (continued)