Emerson PMC-CGM Manuel D’Utilisation
PMC-CGM Installation and Use (6806800D53C)
MIB Description
cgmSys
56
The following table lists all event codes and their severity. Events which cause the module to
give up mastership are marked with an asterisk in the "severity" column.
give up mastership are marked with an asterisk in the "severity" column.
.1.3.1.1.4
cgmEventCode
A pre-defined event code - for details refer to
.
r
.1.3.1.1.5
cgmEventData
Event specific data
r
.1.3.1.1.6
cgmEventDescr
Textual event description
r
Table 5-7 Event Codes and Severity
Code
Severity
Description
inputChanged (1)
Event
The selected PLL input has changed.
lostLock (2)
Event
The T0 PLL lost lock and enters holdover mode.
gainedLock (3)
Event
The PLL gained lock.
nowMaster (4)
Event
The module has acquired mastership.
nowSlave (5)
Event
The module has entered slave mode.
validInputsChanged (6)
Event
The validity or more of the PLL inputs has changed .
selectedInputFailed (7)
Event
The selected clock input has failed.
dpllInitError (10)
Warning
Error while initializing the DPLL.
freqValidationError( 11)
Warning
One of the clock sources measured in the FPGA is out
of range.
of range.
inputStateChange (12)
Event
Reported when a state change is detected by the
activity monitor.
activity monitor.
EventData: Upper 16 bits encode the new state, lower
16 bits encode the input number.
16 bits encode the input number.
State can be
0 (working)
1 (failing)
2 (failed)
3 (recovering)
4 (unknown)
This is the same information as presented in the
cgmInputActivityMonitor element.
cgmInputActivityMonitor element.
lineCardClkError (20)
Warning
Not applicable for PMC-CGM.
lineCardClkSelected (21)
Event
Not applicable for PMC-CGM.
bitsRlof/c (30/34)
Event
"Loss of frame" / "Loss of frame cleared" event
detected on a BITS interface.
detected on a BITS interface.
EventData: The BITS interface on which the event has
been detected (0 or 1).
been detected (0 or 1).
Table 5-6 cgmEventTable (continued)
OID
MIB Object
Description
Access