Epson S1C62 Family Manuel D’Utilisation
Format
ICE CONTROL SOFTWARE ICS62XX
S1C62 FAMILY
EPSON
VIII-21
DEVELOPMENT TOOL REFERENCE MANUAL
DISASSEMBLE LIST
L
#L,
<address 1>
,
<address 2>
#L,
<address 1>
#L
Examples
#L,100,1FF
...
Contents of addresses 100 to 1FF of the program are
0100 FDF RET
displayed disassembled
0101 2FF JP C,FF
: : :
01FF FFF NOP7
: : :
01FF FFF NOP7
#L,200
...
Contents from address 200 onward (22 lines) are displayed
0200 E00 LD A,0
0201 E6F LDPX MX,F
: : :
0215 FFF NOP7
0201 E6F LDPX MX,F
: : :
0215 FFF NOP7
#L
...
One more than the previous address at which the program
0216 FDF RET
stopped are displayed
0217 E05 LD A,5
: : :
022B FFB NOP5
: : :
022B FFB NOP5
#L,100,FFF
0100 FDF RET
: : :
0201 E6F LDPX MX,F
0100 FDF RET
: : :
0201 E6F LDPX MX,F
...
Interrupt via "ESC" key input
#L,100,50
* COMMAND ERROR *
* COMMAND ERROR *
...
Address 1 > address 2 error
#L,100,100
...
Contents of address 100 are disassembled, and executed
0100 FDF RET
normally
#L,3FC
03FC E00 LD A,0
:
03FF 20F JP C,F
03FC E00 LD A,0
:
03FF 20F JP C,F
...
Last program area (3FF address in the case of S1C6S3N7/
6S3B7/6S3L7) is passed, and instruction terminates
6S3B7/6S3L7) is passed, and instruction terminates
#