Chapter 4 Provisioning the TimeProvider
Provisioning Alarms
132  TimeProvider User’s Guide
097-58001-02 Revision G – April 2008
Response Format
<cr><lf><lf>
sid date time<cr><lf>
M
ctag COMPLD<cr><lf>
“<aid>:event id,alarm level”<cr><lf>
“<aid>:event id,alarm level”<cr><lf>
.
.
“<aid>:event id,alarm level”<cr><lf>
;
Sample Command
RTRV-ATTR::SYS:TS1000;
This command causes the TimeProvider to return the alarm levels associated with 
all system-level alarms.
Normal Response
TP-SSU 03-10-24 11:21:20
M
TS1000 COMPLD
"SYS:IOC1EQPT,NA"
"SYS:IOC2EQPT,NA"
"SYS:PWRA,MJ"
"SYS:PWRB,MJ"
"SYS:EXTALM1,MJ"
"SYS:EXTALM2,CR"
"SYS:EXPFAIL,MJ"
;
Retrieving Current Alarms
You can display the current active alarms using the RTRV-ALM command.
RTRV-ALM:[<tid>]:<aid>:[<ctag>];
Field
Description
<aid>
The aid specified in the command
event id
The identifier of the alarm whose level is displayed
alarm level
The value indicates the alarm level that is generated by an alarm 
event:
NR = Not Reported
NA = A non-alarm event
MN = Minor alarm
MJ = Major alarm
CR = Critical alarm