6. Timer Data Organization 
 
 
 The counter data is BCD code. 
 
 The timer automatically adjusts for different month lengths and for leap year. 
 
 The time is indicated in 24-hour format. 
 
 Writes and reads are both performed on an LSB-first basis. 
 
 
MSB 
      
LSB 
 
Second  
( 0 to 59 ) 
 
FDT 
 
s40 
 
s20 
 
s10 
 
s8 
 
s4 
 
s2 
 
s1 
 
 
 
 
 
 
 
 
 
 
Minutes  
( 0 to 59 ) 
 
 
mi40 
 
mi20 
 
mi10 
 
mi8 
 
mi4 
 
mi2 
 
mi1 
 
 
 
 
 
 
 
 
 
 
Hour ( 0 to 23 ) 
 
 
 
h20 
 
h10 
 
h8 
 
h4 
 
h2 
 
h1 
 
 
 
 
 
 
 
 
 
 
Day of the week 
  ( 1 to 7 ) 
 
 
 
 
 
 
w4 
 
w2 
 
w1 
 
 
 
 
 
 
 
 
 
 
Day ( 1 to 31 ) 
 
 
 
d20 
 
d10 
 
d8 
 
d4 
 
d2 
 
d1 
 
 
 
 
 
 
 
 
 
 
Month ( 1 to 12 ) 
 
TM 
 
 
 
mo10 
 
mo8 
 
mo4 
 
mo2 
 
mo1 
 
 
 
 
 
 
 
 
 
 
Year ( 0 to 99 ) 
 
y80 
 
y40 
 
y20 
 
y10 
 
y8 
 
y4 
 
y2 
 
y1 
 
 
 
* bits: Any data may be written to these bits. 
 
 
 
 FDT bit: Supply voltage detection bit 
 
 
 
 This bit is set to “1” when voltage of 1.7 
±
0.3 V or less is detected between V
DD
 and GND. 
 
 
 The FDT bit is cleared if all of the digits up to the year digits are read. 
 
 
 Although this bit can be both read and written, normally set this bit to “0”. 
 
Detection
pulse
V
DD
Mode
FDT bit
V
DET
0.5 s
 Read
0.5 s
 
 
 
 
 
 
The supply voltage detection circuit monitors the supply voltage once every 0.5 seconds; 
                 if the supply voltage is lower than the detection voltage value, the FDT bit is set to “1”. 
 
 
 