Ecom Instruments 40 Manuel D’Utilisation

Page de 9
15
14
Report job 
identification no.:
3015562
FM identification:
I.S. Class I  Division 1 Group A-D T4
6. Technical Data
Ambient temperature Ta:
0 ... +50°C
Storage temperature:
0 ... +50°C
Battery / power supply:
1 x LR14 acc. to IEC; C
Battery operating time:
1 year
Accuracy of 
quartz mechanism:
+15/-5 seconds per month
Dimensions:
(Ex-Time 40)
400 x 60 mm
(Ex-Time 50)
500 x 70 mm 
Weight (incl. batteries):
(Ex-Time 40)
2.0 kg 
(Ex-Time 50)
3.4 kg 
CE labelling:
0102
4. Safety Regulations
The use of the Ex-Time 40 / 50 unit meets the requirements of the
regulations providing that the user observes and applies the require-
ments as laid down in the regulations and that improper and incorrect
use of the unit is avoided.
The following safety regulations must  be complied with:
- The housing of the quartz mechanism and the battery 
compartment must not be opened within the Ex-zone.
- The battery must only be changed outside of the Ex-zone.
- Additional or spare batteries must not be carried in the Ex-zone.
- Only the "type-approved” batteries as listed in these Operating 
- - 
Instructions may be used.
- Ensure that Ex-Time 40 and 50 units are securely attached 
to the wall.
- Precautionary measures must be taken to prevent the unit from 
- -
falling into an area classified as zone 0. 
- The entire back face of the unit must only be cleaned with a 
- - - - -
damp cloth.
5. Ex-Data
EC Certificate
of Conformity no.: 
PTB 02 ATEX 2197 X
Ex-Designation
II 2 G  EEx ia IIC T4
Approved for areas classified as zones 2 and 1, device group II, gas
group C potentially explosive gases, vapours or mist,
temperature class T4
BAL Ex-Time 40/50  29.04.2003  14:46 Uhr  Seite 14