SATO ct4i Manuel D’Utilisation

Page de 74
Unit 4:  Printer Configuration
CT4i Series Operator Manual
4-6
 
Switch 6: VR1 Potentiometer Adjustment mode
Selects the function adjusted by VR1. If DSW6 is Off, VR1 
adjusts the pitch offset value over a range of +/- 3.75 mm. 
When DSW6 is On, VR1 adjusts the print darkness range.
Switch 7: DATA Dump
When ON, the printer will print out the hex value for each 
character received. When OFF, the printer will accept and 
process the data stream in a normal fashion.
Switch 8: Interface Board selection
This switch lets you choose whether to use the factory 
installed interface board connectors, or the user-installable 
Extended Interface board.
If not extended interface board is detected, switching 
DSW8 to Off will not affect the use of the built-in interface.
  
DSW6
Mode
Off
Pitch Offset
On
Print Darkness
Configuration Switch
ON
OFF
1
2
3
4
5
6
7
8
  
DSW7
Mode
Off
DISABLED
On
ENABLED
Configuration Switch
ON
OFF
1
2
3
4
5
6
7
8
  
DSW8
Mode
Off
Use extended 
interface
On
Use internal 
interface
Configuration Switch
ON
OFF