Revision 4 
Automatic Uplink Power Control 
MN/CDM570L.IOM 
 
11.4 Monitoring 
 
The remote demodulator’s value of Eb/No can be monitored at all times, either from the 
front panel (Monitor, AUPC) or via the remote control interface. The resolution of the 
reading is 0.2 dB. For all values greater than or equal to 16 dB, the value 16.0 dB will be 
displayed. As long as framing is enabled, the value will still be available, regardless of 
the AUPC mode, or framing mix. 
 
Also displayed is the current value of Tx power increase. If EDMAC framing is enabled, 
but AUPC is disabled, this will indicate 0.0 dB. This value is also available via the 
remote control interface. 
 
 
 
 
Comtech EF Data strongly cautions against the use of large values of 
permitted power level increase under AUPC control. Users should 
consider using the absolute minimum range necessary to improve rain-
fade margin.
 
CAUTION
 
 