Mocomtech CDM-570L Manuel D’Utilisation

Page de 452
CDM-570/570L Satellite Modem with Optional IP Module 
Revision 4 
IP Module - CLI and Telnet Operation 
MN/CDM570L.IOM 
Menu Options/Fields 
Entry 
Description 
Rx Code Rate 
   1 – 5/16 
   2 – 21/44 
   3 – 1/2 
   4 – 2/3 
   5 – 3/4 
   6 – 7/8 
   7 – 0.95 
   9 – 1/1 
Rx Demodulation  
Sets receive demodulation type  
   1 -- BPSK 
   2 -- QPSK 
   3 -- OQPSK 
   4 – 8-PSK 
   5 -- 16-QAM 
   6 -- 8-QAM 
Rx Spectrum Inversion 
   1 - Normal 
   2 - Inverted 
Rx Data Inversion 
   1 - Normal 
   2 – Inverted 
Rx Descrambling 
   1 - Off 
   2 – On-Default 
   3 – On-IESS-315 
Rx Acquisition Range 
(Sweep Width) 
Valid ranges are from 0 to 200 kHz 
(1 to 32HKz if symbol rate < 625Ksymbol) 
Eb/No Alarm Point 
Valid ranges are from 0.1 to 16.0 
Rx Buffer Size 
   1 -- Disabled 
   2 -- +/-_1024_bits 
   3 -- +/-_2048_bits 
   4 -- +/-_4096_bits 
   5 -- +/-_8192_bits 
   6 -- +/-_16384_bits 
   7 -- +/-_32768_bits 
Save Parameters 
This option allows a user to save the current 
configuration to permanent storage. This configuration 
will be restored on each successive power cycle. 
Exit 
This option allows a user to exit the current menu and 
return to its parent menu. 